뒤로 원문보기 | 미리보기 [ 원문보기시 소비되는 포인트 : 50 포인트 ]
기사명 [특집] 리모델링사례를 통한 리모델링 사업의 발전방향 / [special issue] Remodeling and Aseismatic Reinforcement Design
저자명 윤병익
발행사 대한건축학회
수록사항 건축(대한건축학회지) , v.57 n.10(2013-10)
페이지 시작페이지(34) 총페이지(6)
ISSN 12251666
주제분류 리모델링 / 법규(제도,정책)
요약2 Remodeling business could be satisfied for quality of life and the standard of living highly elevated and as an environment friendly policy which minimize consumption of resources could be said as a strong influential dwelling environment improving method. But the most of the apartment houses which are the objects for remodeling are not designed as aseismatic structures. So, if we make them as horizontal or vertical remodeling of extension, they should be put into aseismatic reinforcement and could not be helped escaping from foundation reinforcement with the increasing of loads. And also, they are not newly constructed buildings. The most of them are over 20 or 30 years old buildings, so we have to think of wornout degree of buildings. Technical testing or system of examination should be checked for the design methods or construction methods from the time of design to construction. Likewise, we are going to examine the reasonable method for the requirements of remodeling business. Firstly, aseismatic reinforcement designs are as following diagram of process. aseismatic performance evaluation of existing buildings → selection of construction for aseismatic reinforcement → aseismatic reinforcement design → aseismatic performance evaluation after reinforcement design → aseismatic reinforcement construction Aseismatic performance evaluation of existing building and aseismatic performance evaluation after reinforcement design are not elasticity analysis method. They are done by nonlinear (non-elasticity) analysis and are effective to show performance characteristics of the structures. And also, they are rational reinforcement design which could be escaped and they were judged on the aseismatic performance of buildings against the designed earthquake. Secondly, foundation reinforcement method is used according to the increasing loads. Because of the direct influence, foundation reinforcement would be minimized. First above all, two more floors of extension in then stories high building would be checked without unpractical foundation reinforcement by lightening finishing loads and partition walls. Merely, in case of the increasing earthquake force or three more stories of extension, foundation reinforcement should be inevitable. Especially, in case of pile foundation, engineering test should come before and experiments and theoretical study must be continued in order to reinforce reasonably. Thirdly, design of remodeling and the process of construction are as follows. Because remodeling construction is different from the new construction, then new criteria and new method of construction is going on the development for the aseismatic reinforcement and general structural reinforcement method. For these, checking and identification about the structural safety from design to construction should be done throughly. So, at the time of designing, an organization of consultation like structural safety technology committee should be established and should be checked the propriety of design about the horizontal and vertical extension. At the time of construction, safe remodeling should be possible with the participation of structural specialists for the technical consultation or career management. At conclusion, remodeling is on the opening stage. Until now, the most rational and safe construction should be gotten with fully mobilization with the use of the accumulated structural engineering technology and the part of new engineering judgment. In that sense, engineering method should be secured according to the raising of preciseness in aseismatic performance evaluation and ensuring of the certainty validation about construction. Successive remodeling business should be followed by all examinations about these all actions systematically after composing of acting system.
소장처 대한건축학회
스크랩하기
추천문헌 이 논문을 열람하신 아우릭 회원님들이 많이 열람하신 논문을 추천해 드립니다.
[특집] 국내 친환경 건축물 사례 분석
정지나 ; 김용석 ; 이승민 - 그린빌딩(한국그린빌딩협의회지) : v.9 n.1 (200803)
[특집] 리모델링 수직증축에 따른 법안 개정방향
정란 - 건축(대한건축학회지) : v.57 n.10 (201310)
[특집] 리모델링 건축설계의 발전 방향
박세희 - 건축(대한건축학회지) : v.57 n.10 (201310)
국내 패시브건축물 설계 및 시공사례
이명주 - 한국그린빌딩협의회 추계학술강연회 논문집 : (200911)
[특집] 장수명 건축의 또 다른 시작 ; 리모델링
김수암 - 건축(대한건축학회지) : v.57 n.10 (201310)
[특집] 리모델링 시장 활성화 대책
장동운 - 건축(대한건축학회지) : v.57 n.10 (201310)
[특집] 리모델링 수직증축에 따른 구조안전성
김승철 - 건축(대한건축학회지) : v.57 n.10 (201310)
[특집] 방수공사의 종류와 시공기술의 이해
안상로 ; 곽규성 ; 최성민 ; 오상근 - 한국건축시공학회지 : v.10 n.4(통권 제42호) (201008)
저탄소 시대의 친환경건축물 기술/사례
조욱희 - (사)한국그린빌딩협의회 창립 10주년 기념대회 : (201004)
[특집] 친환경 건축물의 개념 및 계획 방법
윤종호 - 건축환경설비(한국건축친환경설비학회지) : v.1 n.2 (200710)