요약2 The present aim of the study was to evaluate the conditions of indoor air quality, and to analyze the main influencing factors in occupied apartment units after remodeling. Field measurements were carried out in twenty apartment units, and measurement elements were CO2, CO, PM10, TVOC, HCHO. Moreover, resident interview and researcher observation took place to find out the remodeled contents, and the influencing factors. The results were summarized as follows. The average CO2 in each house were 683~2309 ppm, in which 14 houses exceeded the standard level(1000 ppm) at 70%. The average CO in each house were 0.2~6.1 ppm, way below the standard level(10 ppm). Average PM10 for each house were 0.8~74.8 ㎍/㎥, also below the standard level (100 ㎍/㎥). TVOC average per house were 0~0.3 ppm, in which 11 houses(55%) exceeding the standard level (0.1 ppm) for occupied building and 6 houses(30%) exceeding the standard level(0.58 ppm) for new-built apartment. Average HCHO per house were 0~1.0 ppm, 12 houses(60%) exceeding the standard level(0.1 ppm) for occupied building, and 10 houses(50%) exceeding the standard (0.17 ppm) for new-built apartment. Therefore, the contamination level for CO2, TVOC, and HCHO proved to be at a dangerous level. Influencing factors were classified as general factor, and living factor of measuring date. General factors were revealed as remodeling factor, and ventilation characteristics. Remodeling factor means remodeling amounts, as the level of remodeling amounts increased, the concentration level of HCHO on each houses also increased significantly. The level of TVOC and HCHO in most houses decreased by the date elapsed after remodeling and ventilation methods such as number of times and hours leaving the window open, and the use of bathroom fan, and kitchen hood. Living factors of measuring date were revealed as relative humidity, ventilation time, added remodeling activities, and living activities.
소장처 대한건축학회
스크랩하기
추천문헌 이 논문을 열람하신 아우릭 회원님들이 많이 열람하신 논문을 추천해 드립니다.
[특집] 국내 친환경 건축물 사례 분석
정지나 ; 김용석 ; 이승민 - 그린빌딩(한국그린빌딩협의회지) : v.9 n.1 (200803)
공동주택 미세먼지 현황 및 저감성능 평가에 관한 연구
정민호(Min Ho Chung) ; 배상환(Sang Hwan Bae) ; 이현정(Hyun Jung Lee) - 대한설비공학회 2015년도 하계학술발표대회 : (201506)
창호형 환기장치에 의한 아파트의 환기성능에 대한 연구
장현재(Hyun-Jae Chang) ; 김형진(Hyung-Jin Kim) - 설비공학논문집 : Vol.23 No.03 (201103)
자연환기설비의 성능항목 분석 및 환기성능 평가에 관한 연구
김선숙(Kim Sun-Sook) ; 이윤규(Lee Yun-Gyu) - 대한건축학회논문집 계획계 : v.24 n.12 (200812)
간이 실내 미세먼지 모델을 활용한 건물에서의 미세먼지 유입 및 이동 특성 평가
이병희(Byung Hee Lee) ; 이수환(Su Whan Yee) ; 여명석(Myoung Souk Yeo) - 대한설비공학회 2017년도 하계학술발표대회 : (201706)
에너지절약형 공동주택을 위한 주요 설계변수별 비용효율 분석 및 설계모델 설정
송승영(Song Seung-Yeong) ; 이수진(Lee Soo-Jin) - 대한건축학회논문집 계획계 : v.24 n.11 (200811)
몬테카를로 방법을 이용한 공동주택 환기 전략의 불확실성 분석
김영진(Kim Young-Jin) ; 박철수(Park Cheol-Soo) - 대한건축학회논문집 계획계 : v.24 n.8 (200808)
규범적 건물성능 평가방법
박철수(Park Cheol-Soo) - 대한건축학회논문집 계획계 : v.22 n.11 (200611)
[일반원고] 공동주택의환기시스템적용사례
이창근 - 설비저널(대한설비공학회지) : v.38 n.9 (200909)
실내 미세먼지 농도 예측을 위한 침입계수 및 침착률 산정방법에 관한 연구
이수환(Yee, Su-Whan) ; 이병희(Lee, Byung-Hee) ; 백지민(Back, Ji-Min) ; 강동화(Kang, Dong-Hwa) ; 여명석(Yeo, Myoung-Souk) ; 김광우(Kim, Kwang-Woo) - 대한건축학회논문집 구조계 : Vol.33 No.11 (201711)