요약2 |
The main sources of the new house syndrome(sometimes it called sick building syndrome) are a concentration of formaldehyde (HCHO) and a concentration of total volatile organic compounds(TVOC). I had field measurements of indoor air quality in the apartment unit at medium-size cities(Y city, C city). I measured indoor air temperature, HCHO concentration in 16 units, TVOC concentration in 6 units and air tightness in 7 units. And I measured outdoor air quality, HCHO concentration and TVOC concentration. Mean concentration of HCHO was 357㎍/㎥(2006 standard=120㎍/㎥), mean concentration of TVOC was 3,092㎍/㎥ and mean effective air leakage area was 193 cm2. There was a close relation between the indoor air temperature and HCHO concentration, between the indoor air temperature and TVOC concentration. Air tightness also had relation. |