뒤로 원문보기 | 미리보기 [ 원문보기시 소비되는 포인트 : 100 포인트 ]
논문명 LED조명기구의 면적, 색온도, 광원휘도 변화에 따른 불쾌글레어 평가 / The Evaluation on Discomfort Glare according to the Area, Color Temperature and Luminance of LED Luminaires
저자명 이진숙(Lee Jin-Sook) ; 김병수(Kim Byoung-Soo) ; 한원탁(Han Won-Tak)
발행사 대한건축학회
수록사항 대한건축학회논문집 계획계, v.27 n.8 (2011-08)
페이지 시작페이지(271) 총페이지(8)
ISSN 12269093
주제분류 환경및설비
주제어 불쾌글레어 ; LED조명기구 ; 색온도 ; 광원휘도 ; 면적//Discomfort Glare ; LED Luminaires ; Color Temperature ; Luminance ; Area
요약2 This study intends to ensure the data of influence of which the area, color temperature and luminance of LED luminaires is exercised to discomfort glare. The experiment was progressed in 5 steps. 1)The Mock-up was produced to install the LED luminaires by area which can adjust the color temperature and luminance. 2)We measured the physical properties by experimental variable. 3)We made a comparative analysis of discomfort glare according to the area of LED luminaires. 4)We made a comparative analysis of discomfort glare according to the color temperature of LED luminaires. 5)We made a comparative analysis of discomfort glare according to the luminance of LED luminaires. The experimental result is as following. 1)When the luminance is the same in all the color temperature, the discomfort glare is also increased according as the area of LED luminaires id increased. Also the difference of discomfort glare according to the area was made higher with the higher luminance. And the change of discomfort glare is less according to the area of color temperature of 3300K. 2)The discomfort glare according to the change of color temperature in all the area of luminaires was shown that the discomfort glare was increased with the higher color temperature . The change of discomfort glare is increased with the higher luminance. Also the luminaires with area of 300㎜×300㎜ has less change of discomfort glare according to thecolor temperature in comparison of the other area of luminaires. 3)The discomfort glare according to the change of luminance is also increased with the luminance increased in all the area of luminaires. Also, The change of discomfort glare is increased according to the luminance with the increased area of luminaires. 4)The LED luminaires has the discomfort glare increased with the lower background luminance(with the higher luminance contrast). 5)As much more number of luminous source are shown from table 1 to Table 3, the other accorded variable was highly evaluated for the discomfort glare in Table3.
소장처 대한건축학회
스크랩하기
추천문헌 이 논문을 열람하신 아우릭 회원님들이 많이 열람하신 논문을 추천해 드립니다.
공동주택의 LED조명 적용에 따른 조도 및 에너지 효율 분석
이진숙(Lee Jin-Sook) ; 김소연(Kim So-Yeon) ; 최종문(Choi Jong-Moon) ; 김병수(Kim Byoung-Soo) - 대한건축학회논문집 계획계 : v.27 n.4 (201104)
LED램프를 적용한 사무소 건물의 실내조명환경 및 에너지 성능분석
김병수(Kim Byoung-Soo) ; 임오연(Yim Oh-Yon) - 대한건축학회논문집 계획계 : v.25 n.07 (200907)
LED조명의 거주성 평가에 관한 연구
이진숙(Lee Jin-Sook) ; 박용조(Park Yong-Jo) ; 김원도(Kim Won-Do) ; 김희동(Kim Hee-Dong) ; 주형석(Joo Hyeong-Seok) - 대한건축학회논문집 계획계 : v.26 n.03 (201003)
[논문] LED 조명의 색온도에 따른 집중도 및 시각적 변별력 평가
지순덕 ; 김채복 - 교육시설(한국교육시설학회지) : v.18 n.3 (201105)
CIE 표준 담천공과 청천공 모델의 천공 휘도분포 예측 방법에 관한 연구
김철호(Kim Chul-Ho) ; 김강수(Kim Kang-Soo) - 태양에너지(한국태양에너지학회 논문집) : Vol.36 No.3 (201606)
국내 패시브건축물 설계 및 시공사례
이명주 - 한국그린빌딩협의회 추계학술강연회 논문집 : (200911)
열회수형 환기시스템의 By-pass 제어에 따른 에너지 절감효과 평가
김철호(Kim, Chul-Ho) ; 이승언(Lee, Seung-Eon) ; 김강수(Kim, Kang-Soo) - 추계학술발표대회 : 2015 (201511)
[특집] 국내 친환경 건축물 사례 분석
정지나 ; 김용석 ; 이승민 - 그린빌딩(한국그린빌딩협의회지) : v.9 n.1 (200803)
에너지 절약 요소기술 적용에 따른 High-Performance Building의 에너지 성능 분석
김철호(Kim, Chul-Ho) ; 박두용(Park, Doo-Yong) ; 윤수인(Yun, Su-In) ; 이승언(Lee, Seung-Eon) ; 김강수(Kim, Kang-Soo) - 추계학술발표대회 : 2016 (201611)
고성능 업무용 건축물 구현과 에너지 효율등급 향상을 위한 공조 및 열원 시스템의 에너지 성능 평가
김철호(Kim, Chul-Ho) ; 이승언(Lee, Seung-Eon) ; 김강수(Kim, Kang-Soo) - 한국건축친환경설비학회 논문집 : Vol.10 No.5 (201610)