뒤로 원문보기 | 미리보기 [ 원문보기시 소비되는 포인트 : 100 포인트 ]
논문명 신축 공동주택의 포름알데히드 농도 발생특성과 저감대책에 관한 연구 / A Study on the Formaldehyde Concentration Producing Characteristics and Reducing Method in Newly Built Apartment House
저자명 함진식(Ham Jin-Sik)
발행사 대한건축학회
수록사항 대한건축학회논문집 계획계, v.28 n.09 (2012-09)
페이지 시작페이지(261) 총페이지(8)
ISSN 12269093
주제분류 환경및설비
주제어 신축 공동주택 ; 실내공기질 ; 포름알데히드 ; 가스추적법//Newly Built Apartment House ; Indoor Air Quality ; HCHO ; Tracer Gas Method
요약2 This study intends to find out characteristic of the generation of formaldehyde concentration produced in livingroom and rooms, first, with closed windows , second, with air cleaner operation, photo-catalyst installation, and opened openings in newly constructed apartment house. As a result, the level of formaldehyde concentration was higher than that of Korean Environmental Standard under closed windows case. And, it may be harmful for health by repeating to stay under closed windows. Therefore the solution is required to reduce its concentration. By operating air cleaner with VOCs filter, compared to non-operation, there was about 18% reduction effect of the formaldehyde concentration after 24 hours, though there was no reduction effect of it till 8 hours from starting to measure. Compared to closed windows, there was reduction effect of the formaldehyde concentration in half when photo-catalyst is installed on ceilings, walls, floors, door frames, and doors, etc in main room and room 2. Each room under closed windows had ventilation in every hour. There was huge deviation for the ventilation frequency based on room size and its frequency was getting increased when the opening areas are getting bigger. The level of the formaldehyde concentration in livingroom and main room was below that of Korean Environmental Standard even whole opening by side. However, regardless of opening windows area, room 1 and 2 which have relatively larger areas of windows than their volume can keep it below 0.1?, Korean Environmental Standard. In summary, the ventilation by opening windows in each room was the most noticeable effect to reduce the level of formaldehyde concentration based on evaluation of various cases including air cleaner operation, and photo-catalyst installation.
소장처 대한건축학회
스크랩하기
추천문헌 이 논문을 열람하신 아우릭 회원님들이 많이 열람하신 논문을 추천해 드립니다.
신축공동주택에서 마감자재 적용에 따른 실내공기질 개선 방안
이상형(Lee Sang-Hyung) ; 김형래(Kim Hyung-Rae) - 대한건축학회논문집 계획계 : v.27 n.7 (201107)
[시론] 4차 산업혁명 시대, 건축의 대응
이명식(Lee, Myung-Sik) - 건축(대한건축학회지) : Vol.61 No.05 (201705)
청정건강주택 실내 마감자재 현황 분석에 관한 연구
방현주 ; 최상헌 - 한국실내디자인학회 학술발표대회 논문집 : 제13권 1호 (201105)
[특집] 국내 친환경 건축물 사례 분석
정지나 ; 김용석 ; 이승민 - 그린빌딩(한국그린빌딩협의회지) : v.9 n.1 (200803)
입주전 신축 공동주택의 휘발성유기화합물 및 폼알데하이드 실측에 관한 연구
윤재옥(Yoon, Jae-Ock) - 대한건축학회논문집 계획계 : v.29 n.7 (201307)
시간 경과에 따른 건축마감자재의 포름알데히드 및 VOCs 방출 특성 연구
김상식(Kim Sang-Sik) ; 류기정(Yoo Ki-Cheong) - 대한건축학회논문집 계획계 : v.25 n.08 (200908)
[특집] 공동주택 환기설비와 실내공기질 개선
박철웅 - 건축환경설비(한국건축친환경설비학회지) : Vol.11 No.1 (201701)
공동주택 미세먼지 현황 및 저감성능 평가에 관한 연구
정민호(Min Ho Chung) ; 배상환(Sang Hwan Bae) ; 이현정(Hyun Jung Lee) - 대한설비공학회 2015년도 하계학술발표대회 : (201506)
신축주거의 실내공기질 제어방안 적용에 따른 에너지 소비량 비교분석
최동희(Choi, Dong-Hee) ; 강동화(Kang, Dong-Hwa) - 대한건축학회논문집 계획계 : v.29 n.1 (201301)
[연구논문-건축·주택] 공동주택 지하주차장 결로 방지 방안
홍석진 ; 성기철 ; 김지현 - 대우건설기술 : 통권 제32호 (201008)