사무소 건물 커튼월 시스템의 표면결로 방지 설계기준 / Design Criteria for Preventing Inside Surface Condensation on the Curtain Wall Systems of Office Buildings |
저자명 |
송승영(Song, Seung-Yeong) ; 임아람(Lim, Ah-Ram) ; 송진희(Song, Jin-Hee) ; 임재한(Lim, Jae-Han) ; 이규남(Lee, Kyu-Nam) ; 김영탁(Kim, Yeong-Tak) |
발행사 |
대한건축학회 |
수록사항 |
대한건축학회논문집 계획계, v.28 n.11 (2012-11) |
페이지 |
시작페이지(383) 총페이지(10) |
ISSN |
12269093 |
주제분류 |
환경및설비 |
주제어 |
결로 ; 커튼월 ; 온도계수 ; 사무소건물//Condensation ; Curtain Wall ; Temperature Factor ; Office Building |
요약2 |
Recently, curtain wall system has been applied to much more high rise buildings because of its convenience of construction. However, inside surface condensation on the curtain wall systems still has been a problem. The aim of this study is to suggest design criteria to prevent inside surface condensation on the curtain wall systems of office buildings. A variety of criteria including codes, standards and specifications of Korea and other countries were analyzed and the lowest temperature factor of 0.7 for Seoul was suggested as design criteria. In case of thermally-broken aluminum framed curtain wall system, it was shown that double glazing with soft low-e coating, argon gas, thick-walled plastic spacer and triple glazing with thick-walled plastic spacer could meet the design criteria. |
소장처 |