논문명 |
수열원 냉난방 동시형 히트펌프 시스템의 실외 열교환기 유량제어를 통한 성능개선에 관한 연구 / A Study on the Performance Improvement of a Simultaneous Heating and Cooling Water Source Heat Pump System by Controlling of the Refrigerant Flow Rate in an Outdoor Unit |
저자명 |
배흥희(Heung Hee Bae) ; 이동혁(Dong Hyuk Lee) ; 이상헌(Sanghun Lee); 김병순(Byengsoon Kim) ; 안영철(Young Chull Ahn) |
발행사 |
대한설비공학회 |
수록사항 |
설비공학논문집, Vol.25 No.03 (2013-03) |
페이지 |
시작페이지(131) 총페이지(6) |
ISSN |
1229-6422 |
주제분류 |
환경및설비 |
주제어 |
냉매유량가변 ; 수열원 히트펌프 ; 동시냉난방 ; 운전모드 ; 성능계수//VRF ; Water Source Heat Pump ; Simultaneous cooling and heating ; Operating mode ; COP |
요약2 |
The present study has conducted cycle design and control technology of a water source VRF heat pump system. Previously, study of a simultaneous heating and cooling in an air source VRF heat pump system has been conducted. However, performance data and design methods for simultaneous heating and cooling in a water source VRF heat pump system are limited in the literature, due to various system parameters and operating conditions. In this study, the operating characteristics and performances of a simultaneous heating and cooling heat pump system are carried out, in simultaneous operation modes. Control logics of an EEV are developed for flow rate control to the outdoor unit, and are verified. When the control logics are applied, the simultaneous cooling and heating performances are sufficiently achieved, and system COPs are increased by up to 23.4%. |