논문명 벽면요철을 고려한 동조액체기둥감쇠기의 감쇠비 평가 / An Evaluation of Damping Ratio for Tuned Liquid Column Damper with Embossments / 추계-06. 구조해석
저자명 박병진(Park, Byung-Jin) ; 주영규(Ju, Young K.)
발행사 대한건축학회
수록사항 대한건축학회 학술발표대회 논문집, Vol.36 No.2 (2016-10)
페이지 시작페이지(827) 총페이지(2)
ISSN 2287-5786
주제분류 구조
주제어 동조액체기둥감쇠기 ; 감쇠비 ; 벽면요철 ; 정현스위프//Tuned Liquid Column Damper ; Damping Ratio ; Embossment ; Sine Sweep
요약2 Many researchers have studied additional damping systems to maximize their effectiveness in the tuned liquid column damper(TLCD). There are several additional damping systems such as damping nets, orifices, and the use of highly viscous liquids. In this study, the damping ratio of TLCD with embossments was experimentally evaluated comparing with the one with no embossments. To verify the damping effect of TLCD with embossments, sine sweep vibration test was conducted and damping ratio was evaluated by the half power bandwidth method from the frequency response curve. The test parameters were embossment, effective length of TLCD, and non-dimensional forced amplitude ratio (D/L). According to the test results, the damping ratio of TLCD with embossments increased up to 2.07% comparing with the one with no embossments. The standard deviation of damping ratio according to the change in the effective length ranged from 0.161% to 0.825%. As non-dimensional forced amplitude ratio increased, the damping ratio of TLCD with embossments increased.
소장처 대한건축학회