논문명 도시열섬 완화를 위한 쿨 루프 성능평가 / 서울시 `강남구보건소'를 대상으로 / Performance Evaluation of Cool Roof for Mitigating Urban Heat Island Effects - Case Study of 'GangNam-gu Public Health Center' in Seoul, South Korea -
저자명 박소희(Park, So-Hee) ; 공경배(Kong, Kyoung-Bae) ; 민현준(Min, Hyun-Joon)
발행사 대한건축학회
수록사항 대한건축학회논문집 구조계, Vol.33 No.04 (2017-04)
페이지 시작페이지(55) 총페이지(8)
ISSN 1226-9107
주제분류 환경및설비 / 도시
주제어 쿨 루프 ; 열섬현상 ; 반사율 ; 알베도 ; 방사율 ; 서울시//Cool Roofs ; Heat Island ; Solar Reflection ; Albedo ; Thermal Emittance ; Seoul
요약2 The summer heat due to global warming is getting progressively worse each year. In particular, the unprecedented heat wave in summer 2016, average and maximum temperatures compared to the normal 0.9-1.6 ℃, 0.9-2.2 ℃ higher incidence was observed in the issues of society during July and August. In the case of the city center, as the heat of the daytime is stored in the ground, it does not evaporate normally by dust, lack of greenery and waterfronts led to the heat island phenomenon. Thus, a cool-roof way to reduce the urban heat island phenomenon is getting attention. A cool roof is a method to lower the temperature of the roof surface by increasing the emissivity and solar reflectance. Reduced heat entering the interior roof surface temperature is lowered and helps to reduce summertime indoor temperature. In addition, it is also effective on urban tropical nights mitigated by reducing nighttime heat emitted by the heat storage structure. In this study the effect before and after by installing a cool roof to the actual building will be observed. The subjects measured where surface temperature, room temperature at the same time and environment at the Gangnam Community Health Center by installing a cool roof on 34% of the whole roof surfaces, located in Gangnam, Seoul. Measurement results show that the surface temperature of the roof construction is effective up to 12.9 ℃ reduced measurement period during the summer months, while indoor room temperature showed a difference of up to -1.46 ℃. In winter, the cool roof room’s average indoor temperature differences are -0.17℃ and 31% of the days were warmer compared with the uninstalled room. So the result shows that the cool roof did not significantly effects on increasing the heating load. In order to expand the cool roof enhanced reliability through various case analyses, form and scale, the form of a roof on a building should precede and be reviewed for a variety of environment-friendly techniques and applying green roof, cool roof and solar to be made in accordance with the conditions of the building.
소장처 대한건축학회
스크랩하기
추천문헌 이 논문을 열람하신 아우릭 회원님들이 많이 열람하신 논문을 추천해 드립니다.
[특집] 국내 친환경 건축물 사례 분석
정지나 ; 김용석 ; 이승민 - 그린빌딩(한국그린빌딩협의회지) : v.9 n.1 (200803)
도시열섬 저감을 위한 쿨루프(Cool Roof)의 적용 사례 연구
정민희(Chung, Min-Hee) ; 정주리(Jeoung, Ju-Ri) ; 신창섭(Shin, Chang-Sub) ; 강인성(Kang, In-Sung) ; 박진철(Park, Jin-Chul) - 대한건축학회 학술발표대회 논문집 : Vol.35 No.1 (201504)
[시론] 4차 산업혁명 시대, 건축의 대응
이명식(Lee, Myung-Sik) - 건축(대한건축학회지) : Vol.61 No.05 (201705)
쿨루프 적용에 따른 업무용 건물의 내?외부 온도 저감 효과
송봉근(Song, Bong-Geun) ; 김경아(Kim, Gyeong-Ah) ; 박경훈(Park, Kyung-Hun) - KIEAE Journal : Vol.16 No.6(통권 82호) (201612)
지붕 색상 변화에 따른 건축물의 열환경 및 쿨루프 적용가능성 분석
김경아(Kim, Gyeong-Ah) ; 최정민(Choi, Jeong-Min) ; 박경훈(Park, Kyung-Hun) - 한국건축친환경설비학회 논문집 : Vol.10 No.6 (201612)
[건축환경설비 정보] 친환경건축 기술이 적용된 에너지 저소비형 연구소
김용경 - 건축환경설비(한국건축친환경설비학회지) : v.3 n.3 (200907)
[특집원고] 유량조절 시스템의 적용사례
이창근 ; 박기범 - 설비 | 공조 냉동 위생(한국설비기술협회지) : v.26 n.06 (200906)
소규모 건물모형 실험을 이용한 쿨루프와 그린루프의 효과 평가
김경아(Kim, Gyeong-Ah) ; 박경훈(Park, Kyung-Hun) ; 정다인(Jeong, Da-In) - 한국생태환경건축학회 학술발표대회 논문집 : 통권28호(Vol.15 No.1) (201505)
건물에너지평가도구와 동적해석프로그램의 연간냉난방요구량 해석 및 비교
권장혁 ; 장향인 ; 김민규 ; 박효순 ; 서승직 - 대한설비공학회 하계학술발표회 논문집 : (201206)
ECO2 프로그램을 이용한 표준업무용 건축물의 에너지사용량 예측
송영학 ; 이건호 ; 오세민 ; 이혜련 - 대한건축학회 학술발표대회 논문집 : v.32 n.1(계획계) (201204)