논문명 중층 종합병원 건물의 내진성능평가 / Seismic Performance Evaluation of a Mid-rise General Hospital Building
저자명 김태완(Kim, Taewan) ; 추유림(Chu, Yurim) ; 김승래(Kim, Seung Rae)
발행사 한국지진공학회
수록사항 한국지진공학회 논문집, Vol.21 No.5(통권 118호) (2017-09)
페이지 시작페이지(245) 총페이지(10)
ISSN 1226-525X
주제분류 구조
주제어 //Hospital ; Seismic performance evaluation ; Seismic-force-resisting system ; Analytical model ; Shear propert
요약2 The building which are essential for disaster recovery is classified as a special seismic use group. Especially, achievement of seismic performance is very important for the hospital, so the hospital should be able to maintain its function during and right after an earthquake without significant damage on both structural and non-structural elements. Therefore, this study aimed at checking the seismic performance of a hospital building, but which was limited to structural elements. For the goal, a plan with a configuration of general hospitals in Korea was selected and designed by two different seismic-force-resisting systems. In analytical modeling, the shear behavior of the wall was represented by three inelastic properties as well as elastic. Nonlinear dynamic analyses were conducted to evaluate the performance of structural members. The result showed that the performance of shear walls in the hospital buildings was not satisfied regardless of the seismic-force-resisting systems, while the demands on the beams and columns did not exceed the capacities. This is the result of only considering the shear of the wall as the force-controlled action. When the shear of the wall was modeled as inelastic, the walls were yielded in shear, and as the result, the demands for frames were increased. However, the increase did not exceed the capacities of the frames members. Consequently, since the performance of walls is significant to determine the seismic performance of a hospital building, it will be essential to establish a definite method of modeling shear behavior of walls and judging their performance.
소장처 한국지진공학회
스크랩하기
추천문헌 이 논문을 열람하신 아우릭 회원님들이 많이 열람하신 논문을 추천해 드립니다.
병원 건축물의 내진성능평가 및 보강 사례
최병극(Choi, Byeong-Geuk) ; 백태순(Baek, Tae-Sun) ; 성창원(Seong, Chang-Won) ; 오찬욱(Oh, Chan-Uk) - 대한건축학회 학술발표대회 논문집 : Vol.37 No.2 (201710)
비구조요소의 내진설계기준 비교
장극관(Chang, Kug-Kwan) ; 임영철(Lim, Young-Chul) ; 서대원(Seo, Dae-Won) - 대한건축학회논문집 구조계 : v.29 n.1 (201301)
종합병원건물의 비구조 요소 내진성능평가
김태완(Kim, Taewan) ; 김승래(Kim, Seung RE) ; 추유림(Chu, Yurim) - 한국지진공학회 추계워크샵 발표논문집 : (201709)
[특집] 학교시설 비구조요소의 내진설계, 평가 및 보강
조봉호(Cho, Bong-Ho) ; 유은종(Yu, En-Jong) - 건축(대한건축학회지) : Vol.62 No.04 (201804)
[논문] 대한민국 의료시설의 내진성능 향상을 위한 연구
김장훈 ; 권순정 ; 이충재 - 한국의료복지시설학회지 『의료·복지 건축』 : v.18 n.3(통권 48호) (201208)
종합병원의 비구조요소 내진성능평가를 위한 성능목표 및 성능수준
김태완(Kim, Taewan) ; 김승래(Kim, Seung Re) ; 추유림(Chu, Yurim) ; 반다리 디워스(Bhandari Diwas) - 한국지진공학회 춘계학술발표회 논문집 : (201803)
철근콘크리트 보-기둥 접합부 전단강도 평가
최하영 ; 김병일 ; 이정윤 - 한국콘크리트학회논문집 : Vol.24 No.2 (201204)
비구조 요소-파이프라인 내진 성능 평가
주부석 ; 정우영 - 한국지진공학회 춘계학술발표회 논문집 : (201203)
내진성능평가요령에 따른 4층 RC조 건물의 내진평가
유은종 ; 김용준 ; 김태진 ; 김승진 ; 안충원 - 한국지진공학회 추계워크샵 발표논문집 : (201109)
[특집] 학교건축물의 내진보강 사례
조민주 - 교육시설(한국교육시설학회지) : v.19 n.2 (201203)