뒤로 원문보기 | 미리보기 [ 원문보기시 소비되는 포인트 : 100 포인트 ]
논문명 전기변색 유리 기반 복층화 위치에 따른 열적 및 광학적 성능 비교 / Comparison for Thermal and Optical Performance of Electrochromic Glazing (ECG) with Design Position
저자명 정진화(Jeong, Jin-Hwa) ; 이선한(Lee, Seon-Han) ; 채영태(Chae, Young-Tae)
발행사 한국건축친환경설비학회
수록사항 한국건축친환경설비학회 논문집, Vol.14 No.3 (2020-06)
페이지 시작페이지(271) 총페이지(12)
ISSN 1976-6483
주제분류 환경및설비
주제어 전기변색 유리; 복층화 위치; 열-광학적 특성; 일사 투과; 냉난방장치용량 // Electrochromic glazing; Design position; Thermal and optical characteristics; Solar transmittance; Cooling and heating system sizing
요약2 Recently, smart window be focused on attention with improvement of occupants comfort and building energy performance. Among various smart window, electrochromic glazing (ECG) has outperformed response and can real-time control. In past year, energy simulation and field test of ECG are conducted with various region and building types using control parameters. However, few studies have been performed with design position of ECG in building. This paper analyzed thermal and optical characteristics with ECG position in double layered clear glazing and low-e glazing. It also performed building energy simulation for typical medium office building with different design position of ECG in summer and winter season. First, U-value of ECG+low-e glazing set was higher thermal performance than ECG+clear glazing set. It is more advantageous to position the ECG on the outside than inside position to prevent solar radiation when changed from clear to tint state of ECG. Also, external positioned ECG can contribute to the reduction transmitted solar radiation at clear state of ECG in double clear glazing set. However, internal positioned cleared ECG was more effective to prevent solar radiation in double low-e glazing set because low-e glazing has lower solar transmittance and higher front surface reflectance. The solar transmittance characteristics was compared with different positioned ECG in summer and winter season for typical medium office building. In summer season, external ECG (tint state)+clear/low-e glazing set was more advantageous to prevent transmitted solar radiation by 93% than double layered clear glazing in Incheon, Korea. The ECG+clear glazing set can increase solar radiation compared to ECG+low-e glazing in winter season. Especially, combination of clear glazing+internal ECG outperformed to save heating load than other cases and showed little difference as the amount of transmitted solar radiation was less 10% than double layered clear glazing set for winter season. Finally, ECG+low-e combination can also reduce cooling and heating system sizing by 28%, 26% in approximation with different state of ECG.
소장처 한국건축친환경설비학회
스크랩하기
추천문헌 이 논문을 열람하신 아우릭 회원님들이 많이 열람하신 논문을 추천해 드립니다.
현휘와 에너지성능을 통합 고려한 슬랫형 블라인드의 최적제어 효과에 관한 연구
오명환(Oh Myunh-Hwan) ; 윤종호(Yoon Jong-Ho) - 대한건축학회논문집 계획계 : v.28 n.05 (201205)
스마트 윈도우 기술 동향 및 사례
박상훈 - 건축환경설비(한국건축친환경설비학회지) : Vol.14 No.1 (202001)
주거건물에서의 Electrochromic Window 제어방법에 따른 에너지 절감 효과 비교 분석
김유정(Kim, You-Jeong) ; 이수진(Lee, Soo-Jin) ; 송승영(Song, Seung-Yeong) - 한국건축친환경설비학회 논문집 : Vol.14 No.6 (202012)
창면적비와 SHGC 범위에 따른 SPD를 적용한 반응형 스마트창호의 에너지 성능 평가
고유진(Yujin Ko) ; 홍희기(Hiki Hong) ; 민준기(Joonki Min) - 설비공학논문집 : Vol.32 No.9 (202009)
전기변색유리의 광학특성 및 냉난방부하 분석을 통한 사무소건물 적용성 평가
오명환(Oh, Myung-Hwan) ; 태성호(Tae, Sung-Ho) - 대한건축학회 학술발표대회 논문집 : Vol.38 No.1 (201804)
Electrochromic 창호 적용시 지역별 건물 냉난방 에너지 소비량 절감성능
신재윤(Shin Jae-Yoon) ; 채영태(Chae Young Tae) - 태양에너지(한국태양에너지학회 논문집) : Vol.38 No.5 (201810)
스마트윈도우의 제어 변수 최적화 기법
이명희(Myung Hee Lee) ; 채영태(Young Tae Chae) - 대한설비공학회 동계학술발표회 논문집 : (201711)
스팬드럴용 투광형 결정계 BIPV창호의 후면단열 조건에 따른 연간 온도 및 발전성능 분석 연구
윤종호 ; 오명환 ; 강기환 ; 이재범 - 태양에너지(한국태양에너지학회 논문집) : v.32 n.4 (201208)
국내 패시브건축물 설계 및 시공사례
이명주 - 한국그린빌딩협의회 추계학술강연회 논문집 : (200911)
스마트 윈도우의 제어전략별 건물에너지소비특성
채영태(Young Tae Chae) - 한국생활환경학회지 : Vol.23 No.5 (201610)